Camerapedia
Register
(added internal links)
Tag: Visual edit
 
(One intermediate revision by one other user not shown)
Line 1: Line 1:
 
{{stub}}
 
{{stub}}
  +
[[File:Miranda G.jpg|thumb|220x220px]]
 
The '''[[Miranda]] G''' has an internal [[diaphragm]] coupling. It can work with G and Sensomat lenses, and it would work with Automex and Sensorex lenses, but these lenses do not normally have click stops.
 
The '''[[Miranda]] G''' has an internal [[diaphragm]] coupling. It can work with G and Sensomat lenses, and it would work with Automex and Sensorex lenses, but these lenses do not normally have click stops.
   
Earlier [[Miranda]] lenses with the external PAD (like some [[Exakta]] lenses) can be used, but the release button has to be slowly pressed or a small stop-down button has to be pushed in if stop down metering is used.
+
Earlier [[Miranda]] lenses with the external PAD (like some [[Exakta lenses]]) can be used, but the release button has to be slowly pressed or a small stop-down button has to be pushed in if stop down metering is used.
   
 
The G does not have an internal meter. The meter-prism as on the GT and a non TTL prism can be used, which would also fit early letter series cameras.
 
The G does not have an internal meter. The meter-prism as on the GT and a non TTL prism can be used, which would also fit early letter series cameras.

Latest revision as of 18:34, 25 July 2014

This article is a stub. You can help Camerapedia.org by expanding it.
Miranda G

The Miranda G has an internal diaphragm coupling. It can work with G and Sensomat lenses, and it would work with Automex and Sensorex lenses, but these lenses do not normally have click stops.

Earlier Miranda lenses with the external PAD (like some Exakta lenses) can be used, but the release button has to be slowly pressed or a small stop-down button has to be pushed in if stop down metering is used.

The G does not have an internal meter. The meter-prism as on the GT and a non TTL prism can be used, which would also fit early letter series cameras.

The prisms and accessory viewfinders on the Automex and Sensorex are different and do not fit. The top of the Sensorex / Automex series was taller. Besides the pentaprism and metered prisms, there is a waist-level finder with a pop up magnifier and a critical finder with 5× and 15× magnification. Pentax M42, Nikon F, and Exakta lenses can be adapted and will focus to infinity. But they are manual lenses. A hearing aid cell can be used to replace the mercury cell.

Links[]